ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
0034 00
TROUBLESHOOTING PROCEDURES
UNIT TROUBLESHOOTING PROCEDURES TACTICAL WATER
PURIFICATION SYSTEM (TWPS)
THIS SECTION COVERS:
Chemical Injection System
INITIAL SETUP:
TWPS Set Up
Maintenance Level
Unit
CHEMICAL SYSTEM MALFUNCTIONS
Table 11. Chemical System Troubleshooting.
ITEM
MALFUNCTION
POSSIBLE CAUSES
CORRECTIVE ACTION
1
Chemical pump runs but will
Output dials not set properly.
Always prime pump with speed at 80% and
not prime.
stroke at 80%.
Four-function valve not set properly.
Black priming knob must be turned 1/4
turn to pull it outward.
Foot valve not in semi-vertical position on
Foot valve must be in vertical or semi-
the bottom of the chemical tank.
vertical position.
Clogged foot valve screen.
Remove and clean foot valve screen (WP
Suction or discharge fittings are over-
Loosen fittings slightly. If still not working,
tightened into pump head.
replace suction or discharge valve
Suction cartridge valve leaking.
Replace suction valve assembly (WP
Pump diaphragm ruptured.
2
Chemical pump loses prime.
Chemical bucket level has dropped below
Refill container with solution and re-prime
the suction screen.
Foot valve not in semi-vertical position on
Foot valve must be in vertical or semi-
the bottom of the chemical tank.
vertical position.
Clogged foot valve screen.
Remove and clean foot valve screen (WP
Suction or discharge fittings are over-
Loosen fittings slightly. If still not working,
tightened into pump head.
replace O-rings.
Suction cartridge valve leaking.
Replace suction valve assembly (WP
Pump diaphragm ruptured.
3
Leakage at chemical pump
Worn tubing ends.
Cut about one inch off tubing and
suction, discharge, or return
reconnect.
tubing.
Loose or cracked coupling nut.
Replace suction, discharge, or four-function
Worn valve O-rings.
Replace suction, discharge, or four-function
0034 00-36