ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0040 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR MAINTENANCE PROCEDURES
MICRO-FILTRATION SYSTEM
OUTER SLEEVE
CENTER TUBE
CENTER TUBE O-RINGS
SUBMODULE
CLIPS
BOTTOM FILTRATE CUP
Figure 2. MF Module Sleeve and Lower Clip Removal.
NOTE
Avoid squeezing the submodule screen against the fibers. Do NOT use a metal
lever between the filtrate cup and the headpiece.
j.
Push the top filtrate cup downward until the top filtrate cup is disengaged from the head.
WARNING
Two-person lift. Two people are required to safely move the MF module. Lift with
your legs, not your back. Failure to observe this warning can result in back injury.
NOTE
If the top filtrate cup re-engages in the top head while lifting, the filtrate cups have
not been pushed far enough onto the submodule.
k.
Remove the whole assembly (submodule, filtrate cups, and center tube assembly) by
lifting the bottom filtrate cup until it clears the bottom head.
NOTE
Make sure that there is a clean area to place the submodule, If not, lay down a
cloth and use this as your work area. Place one end of the assembly on the
ground and stand it up.
0040 00-3