ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
0038 00
OPERATOR MAINTENANCE PROCEDURES
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
Table 2. Periodic PMCS for TWPS - Continued.
ITEM
INTERVAL
ITEM TO BE
PROCEDURE
EQUIPMENT
NO.
NOT READY IF:
CHECKED OR
SERVICED
37
Quarterly
Miscellaneous
Spray the following components with the corrosion
components
preventive compound (BII bucket 6)
requiring
P-1 and P-8 throttle linkage
-
corrosion
P-1 and P-8 diesel engine electric starter mounting
-
prevention
hardware
action
P-2 and P-7 exposed motor shaft and shaft sleeve
-
clamp
Exposed threads of turbocharger assembly
-
mounting studs
Exposed threads of RO feed pump assembly
-
mounting studs
Exposed threads of HP pump mounting bolts
-
-
Compressor motor mounting hardware
-
Clamps, bolts, nuts, and gasket retainer for all
-
coupling clamps
Retainer wire ball slots on the three expansion joints
-
at the microfilter inlet and outlet
-
101, PT-102, PT-201 and PT-302
-
(A-TWPS only) Hardware that secures the A-TWPS
-
skid to the flat rack
38
Semi-
Diesel heater
annual
output air filter
39
Semi-
TWPS unit
Unpack, set up, and operate the TWPS.
annual
Perform all Before, During, After, and Weekly PMCS.
Change oil in the air compressor and the P-1 and P-8
pump engines.
Perform preparation for storage procedures
40
Annually
High Pressure
Notify Unit Maintenance to apply grease through the zirk
Pump Motor,
MF and RO
Feed Pump
Motors, and Air
Compressor
Motors
41
Annually
Air Receiver
Check the hydro-test date (stamped on the valve end of
The hydro-test
Tank
the tank). If the date is close to or greater than 5 years
date is 5 years
old, notify Direct Support to have the air receiver tank
old or older.
hydro-tested.
END OF WORK PACKAGE
0038 00-10