ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR MAINTENANCE PROCEDURES
MICRO-FILTRATION SYSTEM
THIS SECTION COVERS:
Replace, Service
INITIAL SETUP:
Maintenance Level
Operator/Crew
Tools
Operator's Tool Kit (BII) (33901161)
MF C-spanner (BII)
References:
Refer to TM 10-4610-309-24P for repair parts information
Personnel Required
Two
Equipment Condition
Standby or short term shutdown with drain down as noted.
GENERAL:
The procedures covered in this work package include:
Micro-Filter Element Replacement
MF Feed Tank Bag Strainer S-1 Cleaning
Basket Strainer S-2 Cleaning
REPLACE
Micro-Filter (MF) Element Replacement:
Parts (TM 10-4610-309-24P):
Module O-rings
MF Element (Submodule)
MF Element O-rings (supplied with MF Element)
Filtrate Cup
Clips
Materials:
Valve seal lubricant (supplied with O-ring kits) (WP 0079, Table 1, item 18)
Clean, dry, lint-free rags (WP 0079, Table 1, item 23)
Personnel:
Two
Equipment Condition:
TWPS In short-term shutdown, anticipated repair less than 4 hours
Replace MF elements (Submodules) MF-1 through MF-12, including the inspection and replacement of
the Submodule O-rings, filtrate cups and clips, as follows:
0040 00-1