ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR MAINTENANCE PROCEDURES
GENERAL MAINTENANCE
THIS SECTION COVERS:
Replace, Assembly
INITIAL SETUP:
Maintenance Level
Operator/Crew
Tools
Operator's Tool Kit (BII) (33901161)
Reference:
Refer to TM 10-4610-309-24P for repair parts information
Personnel Required
One
Equipment Condition
TWPS in Standby Shutdown
GENERAL:
This work package contains information and instructions for replacing, repairing, and assembling
components common to a number of TWPS systems. The procedures covered in this work package
include:
Clamped-On Hose Replacement
Push-On Hose Replacement
Tube Fitting-Connected Tube Replacement
Pipe Coupling Replacement
Sanitary Clamp and Gasket Replacement
Antiseize Pipe Tape Installation
REPLACE
Clamped-On Hose Replacement:
Parts:
Replacement hose
Replacement clamp
Equipment Condition:
TWPS in Standby Shutdown with or without draining down as required
Replace a hose that is clamped onto a fitting as follows (see Figure 1):
1. When replacing a clamped-on drain hose, make sure the TWPS is in Standby Shutdown without
2. For all clamped-on hoses other than a drain hose, make sure the TWPS is in Standby Shutdown
3. Loosen the hose clamp and pull the clamp back down the hose from the fitting.
4. Pull or cut the hose off the fitting.
5. Remove the hose from the fitting at the other end in the same manner.
0045 00-1