ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0050 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
DIESEL ENGINE AND FUEL TANK ASSEMBLY
Recoil Starter Replacement:
Parts (TM 10-4610-309-24P):
Recoil starter assembly
Replace the recoil starter as follows (see Figure 17):
1. Pull the recoil starter cord out a little, secure the rope, slip the handle down the rope and untie or
cut off the knot at the end of the rope.
2. Remove the handle from the rope and pull the rope end out of the eye bolt.
3. Slide the handle back onto the rope end and knot the end of the rope. Let the rope and handle
retract to the recoil starter.
4. Remove the 4 bolts that attach the recoil starter to the cooling fan case. Remove the starter.
5. Attach the new recoil starter to the cooling fan case with the four bolts.
6. Pull the recoil starter rope out past the skid frame, secure the rope, slip the handle down the rope
and untie or cut off the knot at the end of the rope.
7. Remove the handle from the rope and thread the rope through the eye bolt.
8. Slide the handle back onto the rope end and knot the end of the rope. Let the rope and handle
retract to the eye bolt.
EYE BOLT
RECOIL STARTER
STARTER
MOUNTING BOLTS
KNOT
RECOIL STARTER ROPE
COOLING FAN CASE
RECOIL STARTER HANDLE
Figure 17. Recoil Starter Replacement.
0050 00-21