TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
AIR SYSTEM, REDUCED PRESSURE
4. Place old Vent Valve V-910 on a clean workbench and perform the following:
a. Remove the 1/2-in. close nipple from Vent Valve V-910.
b. Clean all disassembled parts.
c. Apply antiseizing tape to both ends of the close nipple.
5. Install new Vent Valve V-910 as follows:
a. Thread the 1/2-in. close nipple into the tee.
b. Thread Vent Valve V-910 onto the close nipple and tighten.
c. Refer to Figure 13 for the correct positioning of Vent Valve V-910.
6. Install the Air System Section 6 assembly onto the TWPS. Refer to REPLACE and Air System
Section 6 Assembly.
7. Check new Vent Valve V-910 and attached piping for leaks.
Air System Air Hose Assemblies Replacement:
Refer to WP 0045, General Operator Maintenance Procedures, or WP 0066, General Unit Maintenance
Procedures, for the procedures for replacing hoses and tubing.
END OF WORK PACKAGE