ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0060 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
OPERATING CONTROL SYSTEM SUB PANEL
b. Position the new module in the 13-slot chassis and press into place.
c. Press the terminal block with its connected wiring onto the new module and secure it with
the two screws.
d. Close the module compartment door.
e. Close and secure the OCP instrument panel using the 14 screws.
13-Slot Chassis Replacement:
Parts:
13-Slot Chassis (TM 10-610-309-24P)
Equipment Condition:
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
Replace the 13-slot chassis on the operating control panel sub-panel as follows:
WARNING
Electrical hazard. Army personnel: make sure that the generator is off and the
TWPS main breaker is off before working on the control panel. Marine Corps
personnel: make sure that the TWPS is disconnected from its power source before
working on the control panel. Failure to observe this warning could result in
serious injury or death from electrical shock.
1. Open the cover to the OCP (see Figure 8).
2. Remove the 14 screws that secure the OCP and swing the instrument panel open.
SCREW (1 OF 14)
COVER
INSTRUMENT PANEL
Figure 8. Opening the OCP Instrument Panel.
0060 00-11