ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0060 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
UNIT MAINTENANCE PROCEDURES
OPERATING CONTROL SYSTEM SUB PANEL
RELAY OUTPUT MODULES
AC INPUT
MODULES
TRIAC OUTPUT MODULE
TOP SCREW
BOTTOM SCREW
TERMINAL BLOCK
OPERATING CONTROL SUB-PANEL
Figure 4. AC Input Module, Relay Output Module, or Triac Output Module Replacement.
4. Install a new AC input module, relay output module, or triac output module as follows:
a. Position the new module in the 13-slot chassis and press into place.
b. Press the terminal block with its connected wiring onto the new module and secure it with
the two screws.
c. Close the module compartment door.
d. Close and secure the OCP instrument panel using the 14 screws.
Analog Output Module Replacement:
Parts:
Analog output module (TM 10-610-309-24P)
Equipment Condition:
Army TWPS: Generator off and TWPS main breaker off
Marine Corps TWPS: TWPS disconnected from power source
Replace the analog output module on the operating control panel sub-panel as follows:
WARNING
Electrical hazard. Army personnel: make sure that the generator is off and the
TWPS main breaker is off before working on the control panel. Marine Corps
personnel: make sure that the TWPS is disconnected from its power source before
working on the control panel. Failure to observe this warning could result in
serious injury or death from electrical shock.
0060 00-7