ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0069 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
DIRECT SUPPORT MAINTENANCE PROCEDURES
MICRO-FILTRATION SYSTEM
5. Remove the MF assembly from the TWPS as follows:
CAUTION
If the MF assembly is set down vertically when it is removed from the TWPS, the
MF module tubes can compress down unless bracing is placed between the MF
assembly headers. It is recommended that the MF assembly headers be braced
before the assembly is removed.
a. Insert a brace, such as a 2x4 length of wood or metal, between the upper and lower MF
assembly headers at both ends of the assembly and secure with duct tape, rope, or some
other temporary means of keeping the brace in place (see Figure 5).
DUCT TAPE
TEMPORARY BRACE
Figure 5. Temporary Bracing for MF Assembly Removal.
0069 00-6