ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
0069 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
DIRECT SUPPORT MAINTENANCE PROCEDURES
MICRO-FILTRATION SYSTEM
CAUTION
Potential for damaging the MF assembly inlet and outlet pipes. Lifting straps
should not be placed under the MF assembly inlet and outlet pipes. The pipes are
not designed to support the weight of the MF assembly. Failure to observe this
warning could result in damage to the pipes.
b. Attach one lifting strap under the lower spacers at the top ends of the MF assembly.
c. Remove the slack from the straps, but do not apply any lifting pressure.
d. Remove the two hex cap screws, four flat washers, and two nuts that secure the top left
mounting bracket to the TWPS frame (as viewed from the back of the TWPS).
e. Remove the two hex cap screws, one lock washer, and three flat washers that secure the
top right mounting bracket to the TWPS frame (as viewed from the back of the TWPS).
f. Remove the four hex cap screws, eight flat washers, and four nuts that secure the two
bottom mounting brackets to the TWPS frame.
g. Slide the bottom mounting brackets off the MF assembly as the assembly is raised off the
TWPS.
UPPER SPACER
LIFTING STRAP
UNDER LOWER SPACERS
INLET PIPES
BOTTOM MOUNTING BRACKET
Figure 6. TWPS MF Assembly Removal.
0069 00-7