ARMY TM 10-4610-309-14
MARINE CORPS TM 10802A-14/1
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
DIRECT SUPPORT MAINTENANCE PROCEDURES
MICRO-FILTRATION SYSTEM
THIS SECTION COVERS:
Repair
INITIAL SETUP:
Maintenance Level
Direct Support
Tools
Lifting Straps (2)
References:
Refer to TM 10-4610-309-24P for repair parts information
Personnel Required
Two
Equipment Condition
TWPS in short term shutdown
GENERAL:
This work package provides procedures for repairing components in the Micro-Filtration (MF) Assembly.
The steps covered include:
MF Assembly Removal
MF Assembly Disassembly and Repair
MF Assembly Reassembly
MF Assembly Installation
MICRO-FILTRATION ASSEMBLY REPAIR:
Parts (TM 10-4610-309-24P):
O-Ring, 10540577
O-Ring, 10540578
Materials:
Lubricant, valve seal (WP 0079, Table 1, item 26)
Clean, dry lint-free rags (WP 0079, Table 1, item 33)
Equipment Condition:
TWPS in Short Term Shutdown, anticipated over 4 hours but less than 54 hours (WP 0017)
Repair the MF filter module assembly, including inspecting and replacing the module head O-rings, as
follows:
NOTE
Tag each component as it is removed in the following steps, to make sure it is
reinstalled in the same location.
0069 00-1