TM 10-4610-310-14
0015 00
SETUP FOR COLD WEATHER OPERATION continued
WARNING
Exhaust gases contain deadly carbon monoxide. Do not operate unit in an enclosed area
unless exhaust has been properly vented outside. Place as far away from personnel,
occupied vehicles, equipment, and shelters as possible. Failure to follow this warning may
result in serious personal injury or death from carbon monoxide poisoning.
WARNING
Hearing protection must be worn at all times when the diesel engine is being operated inside
the tent. Failure to follow this warning may result in hearing damage to the personnel.
19. Route the exhaust hose to the outside of the heated enclosure, away from personnel, equipment, and dry
grass and brush.
20. Install battery in the carbon monoxide detector and test for operation.
21. Mount carbon monoxide detector above the high-pressure pump module diesel engine at least 6 foot high.
COLD WEATHER DRAIN PROCEDURE
CAUTION
Drain all components of LWP thoroughly if the unit is not operated during freezing weather.
Failure to follow this caution may result in damage to equipment.
1. Shut the LWP down and drain in accordance with WP 0013 00.
2. Drain all liquid that is remaining in the hoses, membranes, piping, tubing, tanks, service pumps and high-
pressure pump.
a. Turn the service pumps upside down to drain them.
b. Disconnect all the hoses from the UF module and open all the drain valves. Disconnect the inlet
hose to the filtrate tank. Loosen the unions on the bottom of the UF membrane cartridges to
thoroughly drain the system. The module can be tilted slightly to aid in draining. See WP 0013
00 for draining the modules.
c.
Disconnect all the hoses from the high-pressure module, chemical module, and RO module.
d. Drain all the water out from the modules. Tilt the modules to aid draining.
e. Open all the sampling valves and the reject valve on the RO module.
f.
Drain all the fabric tanks and hoses.
0015 00-7