TM 10-4610-310-14
0015 00
COLD WEATHER OPERATION - continued
8. Wrap the pump thermal blanket on raw water pump. See Figure 2.
9. Ensure that the stainless steel fitting is not exposed to the elements.
THERMAL
RAW WATER
BLANKET
PUMP
WITH CABLE
STAINLESS
STEEL
FITTING
Figure 2. Raw Water Service Pump Electric Thermal Blanket.
WARNING
Inspect all electrical cables for damage before energizing any equipment. Failure to observe
this warning could result in personnel injury and/or death and damage to the equipment.
1. All power cables/extension cables for cold weather kit connect to the power distribution panel. The
receptacles J1 through J5 are compatible with all connectors from the electric thermal blankets and raw
water service pump blanket. See Figure 3.
POWER
SWITCH
POWER
CABLE
20 AMP, 125-VOLT
RECEPTACLE (5)
Figure 3. Power Distribution Panel.