TM 10-4610-310-14
0103 00
REMOVAL - continued
9. Remove four nuts, bolts, and washers, and two mounting brackets securing chemical pump to the module.
See Figure 3.
NOTE
Pump mounting brackets are different sizes and not interchangeable.
10. Keep mounting brackets with appropriate chemical pump.
11. Remove chemical pump from the chemical module.
BRACKET
CHEMICAL PUMP
BOLT
WASHERS
NUT
Figure 3. Chemical Pump Mounting Brackets.
INSTALLATION
Install chemical pump onto the chemical module.
1.
Install mounting brackets.
2.
Secure chemical pump and brackets with four bolts, washers, and nuts. Tighten securely.
3.
Feed the wires through the hub.
4.
Properly install wires markers on wiring.
5.
Connect the wires on the terminal block. See Figure 2.
6.
Install cover on chemical module junction box assembly. Secure with four.
7.
8.
9.
END OF WORK PACKAGE