TM 10-4610-310-14
0128 00
REMOVAL continued
Figure 2. HP Module Junction Box Assembly.
3. Remove the wiring from the terminal block. Note the location of the wires and their numbers.
4. Remove high-pressure switch conduit from hub (6).
5. Remove low-pressure switch conduit from hub (3).
6. Remove emergency shutoff switch conduit from hub (7).
7. Remove control panel cable from hub (8).
8. Remove four screws (1), nuts (5), and washers (4) from junction box (2).
9. Remove the end stops on the mounting rail and pry off the terminal block from the mounting rail. See Figure
3.
TERMINAL
BLOCK
Figure 3. Terminal Block.
0128 00-2