TM 3-4230-204-12&P
3
2
a. Carefully pour the remaining DS2 fluid
out of the E tapped hole (13) from which
the steel machine bolt was removed.
b. After removing DS2/fluid from container
(10), flush inside and outside surfaces
with mixture of water general purpose
detergent.
c. Agitate container (10) in clean hot
water.
Unscrew and remove the steel machine bolt
(11) with the copper flat washer (12) attached.
4
a. Turn spray head assembly (9) upside down.
b. Press thumb lever (14) while pouring water and general purpose
detergent mixture slowly into the strainer (15).
c. Agitate spray head assembly in clean hot water.
NOTE
The flow of water coming out of the nozzle hole will be
very slow. If a large container is available, agitating the
spray head assembly with thumb lever pressed will
force the mixture through the siphon tube faster.
4-13