TM 3-4230-204-12&P
Section V. UNIT MAINTENANCE PROCEDURES
4-7.
DECONTAMINATING APPARATUS, ABC-M11. I
This task covers:
a. Installation
d. Inspection/Repair
b. Cleaning
e. Reassembly
c. Disassembly
INITIAL SETUP
Required
Tools and Special Tools
One quartermaster and chemical equipment repairman MOS 63J or
General Mechanic's Automotive Tool Kit SC 5180-90-CL-N26
equivalent MOS or personnel normally assigned in support of this
equipment.
Materials/Parts
Chemical and oil protective gloves (item 8, app E)
References
Corrosion inhibitor (item 10, app E)
Refer to applicable TM for vehicle/equipment until M11 DECON is attached.
Dry cleaning solvent (SD) (item 5, app E)
Epoxy coating (item 7, app E)
General Safety Instructions
Forest green polyurethane coating (item 11, app E)
General purpose detergent (item 4, app E)
Safety goggles will be worn during drilling of mounting holes. NBC
Pressure sensitive tape (item 14, app E)
clothing including mask, hood, and rubber gloves must be worn when
Silicon compound (item 13, app E)
handling DS2 or equipment exposed to DS2 until equipment is cleaned.
Wiping rag (item 12, app E)
Protective gloves shall be worn while using dry cleaning solvent.
Yellow enamel (item 6, app E)
INSTALLATION
1
WARNING
DS2 is combustible. M11 DECON should not be mounted near a fire extinguisher. This could cause confusion between the M11
DECON and fire extinguisher during an emergency.
Wear goggles for eye protection when drilling mounting holes.
4-8