TM 3-4230-209-10
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3. Inspect CIRCUIT BREAKER mounted on the control panel to
determine if it has been tripped.
Reset CIRCUIT BREAKER by turning switch to OFF
and then back to ON.
Step 4. Inspect engine fuse mounted on the engine regulator-rectifier
(as illustrated). Make sure it is not burned out.
Replace fuse (TM 92805-25914) with the spare fuse
and then replace the spare fuse with a new fuse.
2. PUMP PRESSURE LOW OR FALLING.
Step 1.
Check engine speed indicated by
RPMs on
TACHOMETER.
Increase the engine speed by rotating the throttle
RPM. If RPMs are not satisfactory, notify unit
maintenance.
Change 2 3-5