TM 3-4230-209-10
Table 3-1. TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. PUMP PRESSURE LOW OR FALLING (CONT).
Step 2. Check drive belts for proper tension with tensiometer. Adjust drive
Step 3. Check to see that VALVE NO. 4 PRIME (as illustrated) is closed
after priming pump and before prime-detergent tank is empty.
a. Close VALVE NO. 4 PRIME.
b. Refill prime-detergent tank.
c. Open VALVE NO. 4 PRIME and prime pump.
d. Close VALVE NO. 4 PRIME before tank is empty.
3. PUMP INOPERATIVE (FAILS TO OPERATE).
Step 1. Check to see that VALVE NO. 4 PRIME is closed after priming
pump and before prime-detergent tank is empty.
a. Close VALVE NO. 4 PRIME.
b. Refill prime-detergent tank.
c. Open VALVE NO. 4 PRIME and prime pump.
d. Close VALVE NO. 4 PRIME before tank is empty.
Step 2. To check to see if VALVE NOS. 1,2, or 3 are closed, open one or
more of these valves. See instruction on starting procedure plate.
3-6