TM 3-4230-209-10
Table 3-1. TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Check to determine if water flow is too slow.
Increase water flow by opening valve No. 1 completely.
Step 3. If shower assembly is used, check for clogged strainer in shower
assembly.
Stop equipment and clean screen in strainer (item 3,
Step 4. If discharge hoses are used, check for clogged discharge hoses.
Flush discharge hoses.
3. WATER NOT HOT ENOUGH.
Step 1. Check for rapid flow rate of water.
Adjust valve No. 1 to slow proper flow rate and correct tem-
perature. If correct temperature cannot be reached, notify
unit maintenance.
Step 2. Check for leaking fuel lines and defective or worn fuel pump. See
Burner Sputters Out, steps 9,10, and 11.
Step 3. Check for improperly connected hoses.
Connect hoses properly.
3-12