TM 3-4230-237-10
0007 00
SPRAYING WATER FROM TANK - Continued
8
7
2
2. Connect one end of suction hose (2) to the tank drain valve (7) and the other end to the pump unit connection (8).
3. Cap the upper and lower discharge connection.
4. Open tank drain valve (7).
5. Prime the pump and start the pump unit (Page 0006 00-1). Unreel the discharge hoses (5) from the two hose reels.
6. To spray from the upper reel, open VALVES NO. 1 and 3. To spray from the lower reel, open VALVES NO. 1 and 2.
Open valve on gun assembly to spray. Open the slurry nozzle's orifice and deflector assembly to produce the desired spray
pattern.
5
NOTE
The pump discharge pressure gage should indicate approximately 105 psi while spraying.
7. After the spraying mission is complete, stop the pump unit (Page 0006 00-7). Clean and store the apparatus according to
0007 00-3