TM 3-4230-237-10
0007 00
LOADING TANK FROM A PRESSURE SOURCE
CAUTION
Always use the cleanest water available. Grit or dirt in water under pressure will damage the pump and
hose nozzles.
1
NOTE
The working capacity of the tank unit is approximately 447 gallons. When water only is to be loaded, fill
the tank to the 447 gallon capacity. When STB decontaminating agent is to be added, fill the tank with
only 225 gallons of water. If necessary, remove screen to read the tank liquid level indicator (1).
2
9
10
1. Remove cover (9). Load water from a hydrant or tank truck by inserting a hose (10) (not part of the decontaminating
apparatus) in the hopper-blender.
NOTE
An alternate method of filling from a pressure source is to use the suction hose provided with the
decontaminating apparatus. First, attach one end to the tank drain valve. Then, using a suitable adapter
(not part of the decontaminating apparatus), connect the opposite end of the suction hose to the pressure
source. Open the tank drain valve and monitor the filling progress on the tank liquid level indicator
because it can be very rapid.