TM 3-4230-237-10
0019 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) Continued
Table 1. Quarterly and Annual PMCS for M12A1 DED Decontaminating Apparatus - Continued.
Procedure
Not Fully
Item
Interval
Man
Item to be
No.
Hour
Checked/
Mission
Serviced
Capable If:
a. Inspect that lube fitting (1) and breather (2) are
20
QUARTERLY
Centrifugal
not broken or missing.
Pump
2
1
b. Lubricate according to Lubrication Instructions
20
(WP 0020 00).
WARNING
Fire and explosion danger exist
when solvent cleaning
compound is used. Make sure
that equipment is dry before
operations begin.
b. Lubricate in accordance with Lubrication
c. Wash outside of pump with solvent cleaning
thoroughly. Remove rust and corrosion with a
0019 00-11