LUBRICATION INSTRUCTIONS Continued
NOTES: Continued
10. DETERGENT and FUEL TANKS -- During inactive periods, fog interior of prime and detergent tank and fuel tank with
PL-M or PL-S.
11. IDLE TIME -- If the apparatus is to be idle for greater than 24 hours, lubricate the pump by pouring 3 pints of PL-M or
PL-S mixed with 3 gallons of water into the prime detergent tank. Open valve No. 4 and allow the mixture to run into
the pump. Start the pump unit and operate for 30 seconds. Stop the pump unit. Open the pump drain valve and allow
the mixture to run out. Check that prime detergent tank is empty. Close the pump drain valve and valve no. 4. For idle
time greater than 48 hours, follow the above procedures and, in addition, wipe exterior surfaces of pump, piping, and
valves with a cloth dampened with PL-M or PL-S.
12. Coat battery terminals with GAA.
13. HINGED PANELS -- Lubricate hinges with PL-S.
END OF WORK PACKAGE