TM 5-3800-205-10-2
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
f. Check that front inspection cover is f. Front inspection cover is
49
After
Rear Deck
damaged or missing or
present, in good condition, and
(Con't)
and Tank
will not close.
closed.
Assembly
g. Ensure that all hydraulic, fuel, elec- g. Lines are damaged. Class
III hydraulic leaks are
trical, and air lines are not damaged.
evident. Any air or fuel
Ensure that protective shields are in
leaks are evident.
proper position.
WARNING
DO NOT perform fuel system checks, inspections or mainte-
nance while smoking or near fire, flames or sparks. Fuel may
ignite, causing damage to vehicle and injury or death to per-
sonnel.
Operating personnel must wear fuel-resistant gloves when han-
dling fuels. If exposed to fuel, promptly wash exposed skin
and change fuel-soaked clothing. Failure to do so may result in
injury to personnel.
Ensure access panel is securely supported in open position.
Failure to do so could cause panel to slam shut, causing serious
injury to personnel.
Fuel, Brake, a. Open access panel at rear of
50
After
machine and secure in open position
and Hydrau-
with prop rod.
lic
System
Components
b. Check the following components b. Class III hydraulic fluid
leaks are evident. Any
for signs of leaks and/or damaged or
brake fluid or fuel leaks
missing parts.
are evident. Damaged or
(1) fuel/water separator;
missing parts are noted.
(2) fuel lines;
(3) brake fluid reservoir;
(4) air/hydraulic brake cylinder and
lines; and
(5) water pump hydraulic hoses.
c. Open drain valve on fuel/water sep-
arator and drain water and fuel into
a suitable container. Close valve.
d.
0013 00-37