TM 5-3800-205-10-2
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
50
After
Fuel, Brake,
(Con't)
and Hydrau-
lic
System
Components
WATER PUMP
BRAKE FLUID
HYDRAULIC HOSE
RESERVOIR
FUEL/WATER
PROP
SEPARATOR
ROD
ACCESS
PANEL
BACKUP
AIR/HYDRAULIC BRAKE
ALARM
CYLINDER (HIDDEN)
FUEL
DRAIN
390-1961
LINES
VALVE
51
After
Backup
a. Check for damage to backup alarm.
a. Damage
that
would
Alarm
impair operation is evi-
dent.
b. Close access panel and secure with
two latches.
a. Visually check tire for cuts or a. Tire has cuts or bulges in
52
After
Rear Wheel
tread or sidewall area or
and Tire
bulges in tread or sidewall area.
other damage that would
Check for uneven wear or underin-
impair operation.
flation. Look for stones or other for-
eign material embedded in tread or
sidewall area. Remove stones or
other foreign material if found.
b. Check for loose or missing wheel b. Missing wheel studs, lug
nuts, rim lock or dam-
studs, lug nuts, rim lock, and valve
aged valve stem are
stem with cap.
noted.
0013 00-38