TM 5-3800-205-10-2
ENGINE AIR PRECLEANER AND AIR CLEANER ASSEMBLY SERVICING - CONTINUED
0014 00
ENGINE AIR CLEANER ASSEMBLY SERVICING - CONTINUED
NOTE
Replace secondary element every third primary element replacement.
5.
Remove secondary element from air cleaner housing. Obtain a replacement if damaged or if primary element is being
replaced for the 3rd time.
6.
Wipe inside of air cleaner housing clean with a rag.
AIR CLEANER
SECONDARY
HOUSING
ELEMENT
390-1014
CAUTION
DO NOT use a damaged primary element. Engine damage can result.
7.
Inspect primary element. If pleats or seals are damaged, discard primary element.
NOTE
A primary element may be cleaned a maximum of six times. Also replace primary element if it has been in
service for one year.
8.
If primary element is OK, clean as follows:
0014 00-4