TM 5-3800-205-10-2
RAIL TRANSPORT - CONTINUED
0020 00
RETURN MACHINE TO OPERATIONAL CONFIGURATION - CONTINUED
CAUTION
Always wipe ends clean prior to disconnecting hydraulic lines. Ensure ends are clean prior to reconnecting.
Failure to do so may introduce contamination into hydraulic system.
5.
OCONUS ONLY: Install two water pump motor hydraulic hoses as follows:
a.
Remove straps and release hoses from stowage at slings points on top of tank.
NOTE
All quick disconnect connections are made the same way. Be sure to turn quick disconnect collar a half turn
after connecting to lock connection.
b.
Remove dust caps and connect two water pump motor hydraulic hoses to quick disconnects at top of tank. Turn
each quick disconnect collar a half turn after connecting to lock connection.
WATER PUMP MOTOR
SLING
SLING
HYDRAULIC HOSES
POINT
POINT
QUICK
DISCON-
NECTS
390-1969
WATER PUMP MOTOR
STRAP
HYDRAULIC HOSES
STRAP
390-1466
0020 00-28