TM 5-3800-205-23-3
WATER PUMP HOUSING REPLACEMENT - CONTINUED
0039 00
REMOVAL - CONTINUED
2.
Remove two nuts (6), bolts (7), coupling (8), and seal (9) from suction pipe (11) and flange (10).
8,9
(HIDDEN)
7
6
11
10
NOTE
Do not remove mounting bolts until water pump housing is secured with lifting device.
3.
Loosen, but do not remove, two nuts (12), lockwashers (13), four flatwashers (14), and two bolts (15) on mounting
bracket (16). Move water pump housing (17) as necessary to position nylon sling and suitable lifting device on housing.
4.
Remove two nuts (12), lockwashers (13), four flatwashers (14), and two bolts (15) from mounting bracket (16) and
water distributor frame (18). Discard lockwashers.
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during the
procedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear
of heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury
to personnel.
NOTE
Water pump housing weighs 115 lb (52 kg).
5.
Remove water pump housing (17) and mounting bracket (16) from machine and place on suitable blocks.