TM 5-3800-205-23-3
WATER PUMP MAINTENANCE - CONTINUED
0038 00
INSTALLATION
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during the
procedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear
of heavy parts supported only by lifting device. Failure to follow this warning may result in death or injury
to personnel.
CAUTION
Use care when handling power head and diffuser. Diffuser is loose and could fall from power head, resulting
in damage to diffuser.
NOTE
Power head weighs 115 lb (52 kg).
1.
Ensure O-ring (9) is positioned in diffuser (7).
8
7
2
9
390-1575
2.
Lubricate with oil and install new gasket (8) on power head (2). Position diffuser (7) on power head.
3.
Position nylon sling on power head (2) assembly. With assistance, install power head assembly on pump housing (4).
Ensure alignment marks on adapter (3) and pump housing (4) are aligned.
0038 00-8