TM 5-4610-218-34
Table 2-1. Troubleshooting-(Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Check for a worn or broken valve spring.
Step 3. Inspect the air release valve check valve for clogs or corrosion.
Step 4. Inspect for broken air release valve tubing.
7. AIR RELEASE VALVE FAILS TO RELEASE, OR RELEASES TOO SLOW.
Step 1. Check for a bent or corroded diaphragm push rod.
Step 2. Inspect the check valve for clogs, corrosion, or defects.
Step 3. Check for a crimped or clogged tube assembly.
8. FILTER PUMP MOTOR WILL NOT RUN, OR IS NOISY DURING OPERATION.
Step 1. If the pump motor does not run, check for defective wiring.
Step 2. If the pump motor does not run, check for open or shorted field or stator wiring.
Step 3. If the pump motor is noisy during operation, check for a bent rotor shaft.
Step 4. If the pump motor is noisy during operation, inspect the bearings for wear or cracks.
GENERAL
MAINTENANCE
Section III.
(4) Erdlator agitator shaft assembly. Re-
2-5. General Maintenance.
pair, replace.
a. General. This paragraph contains the main-
(5) Low water level warning buzzer. Test,
tenance functions for the major components/assem-
replace.
blies as authorized by the Maintenance Allocation
Chart to direct support and general support mainte-
(6) Electrical control cabinet. Replace.
nance personnel that are contained in the following
(7) Chemical slurry feeder. Repair, replace.
paragraphs of this manual. Below, is a breakdown of
(8) Diatomite dilution tank. Replace.
those maintenance functions allocated to direct
support, and a breakdown of the maintenance func-
(9) Chemical slurry feeder speed reducer.
tions allocated to general support.
Repair.
b. Direct Support.
(10) Diatomite filter air release valve. Re-
pair.
(1) Erdlator tank. Repair, replace.
(11) Diatomite filter pump motor. Repair,
(2) Ladder assembly. Repair.
(3) Erdlator agitator speed reducer. Re- overhaul.
c. General Support.
pair.
2-3