TM 5-4610-218-34
Table 2-1. Troubleshoting-(Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Inspect the main power cable leads for improper connections.
Connect the cable leads (FO 2).
Step 3. Check for a defective main power cable.
Replace a defective main power cable (FO 2).
3. SPEED REDUCERS BIND OR RUN NOISY.
Step 1. If the speed reducer binds, check for a worn or bent shaft.
Replace a defective shaft (para 4-2 and 5-3).
Step 2. If the speed reducer binds, check for a lack of proper lubrication
Lubricate in accordance with LO 5-4610-218-12.
.
Step 3. If the speed reducer runs noisy, check for worn or chipped gears.
Replace worn or defective gears (para. 4-2 and 5-3).
Step 4. If the speed reducer runs noisy, check for a lack of proper lubrication
Lubricate in accordance with LO 5-4610-218-12.
CHEMICAL FEED EQUIPMENT
4. CHEMICAL SLURRY FEEDER WILL NOT RUN, OR RUNS HOT.
Step 1. If the chemical slurry feeder will not run, check for a broken through shaft.
Step 2. If the chemical slurry feeder runs hot, check for worn or broken shaft bearings.
Step 3. If the chemical slurry feeder runs hot, inspect for a bent or twisted housing.
5. CHEMICAL SOLUTION FEEDER WILL NOT RUN, OR RUNS NOISY.
Step 1. If the chemical solution feeder does not run, check for a broken feeder shaft.
Step 2. If the chemical solution feeder does not run, check for a defective receptacle base.
Step 3. If the chemical solution feeder does not run, check for broken internal wiring.
Step 4. If the chemical solution feeder runs noisy, inspect the bearings and sleeves for wear.
Step 5. If the chemical solution feeder runs noisy, see if the spur gears are worn or broken
5.1 CHEMICAL SOLUTION FEEDER WILL NOT RUN, OR RUNS NOSY (Raider Model
only).
Step 1. Inspect motor worm gear for damage.
Replace feeder.
2-2 Change 2