TM 5-4610-223-12
d.
Raw Water Pump.
(1)
Disconnect raw pump extension cable and male plug connector (2, fig. 2-7) from female plug receptacle
(2).
(2)
Withdraw extension cable from van body cable outlet (7, fig. 1-2) and disconnect it from raw water pump
cable (19, fig. 2-6).
(3)
Roll cable (19) on pump frame bracket (16, fig. 2-19).
(4)
Place raw water pump (11, fig. 1-3) on mounting pads in right rear section of van body floor. Secure
pump with four 3/8-16 x 1 1/4-inch capscrews with lockwashers.
CAUTION
Identify the pump so that the raw water pump will not be used for distribution without first being
cleaned.
e.
Water Distribution Hose and Fittings.
(1)
Remove nozzles (37, fig. 2-6) from adapters (38).
(2)
Remove adapters (38) from two distribution pump discharge hoses (39).
(3)
Disconnect distribution pump discharge hoses (39) from siamese connection (40), and store hoses in van
body.
(4)
Remove siamese connection (40), from elbow (21).
(5)
Store siamese connection (40), adapters (38), and nozzles (37) in the accessory stowage box (14, fig. 1-
3).
(6)
Disconnect hose (1, fig. 2-6) from suction side of pump.
(7)
Disconnect other end of hose (1) from adapter (2).
(8)
Remove adapter (2) from valve (3).
(9)
Remove valve (3) from adapter (4) and remove adapter (4) from male outlet second storage tank (6).
(10)
Store fittings in stowage box and lay hoses aside out of way.
f.
Distribution Pump.
(1)
If the electric driven water distribution pump was installed, disconnect extension cable and male plug
connector from female connector.
(2)
Withdraw extension cable from van body cable outlet.
4-18