TM 5-4610-223-12
(4) Allow adequate spare for locating and installing the component items and for haul roads for the water
transporting vehicles.
(5
Select a firm level footing for the truck wheels.
(6
Locate the unit as close to the water source as possible, preferably not more than 50 feet (15 m) away.
WARNING
Avoid taking water near a bathing area, sewer outlet or latrine.
r.
Truck-Mounted Water Purification Unit.
(1) Position the truck-mounted water purification unit (15, fig. 2-6) in its selected location at the water site.
Provide a firm footing for wheels and jacks by digging ditches and Installing blocks or timber under the wheels and jacks
to prevent setting. Set truck chassis handbrake, leave the transmission in gear and place
Figure 2-6. Water Purification and Supporting Equipment in Operating Position.
Change 4 2-14.1/(2-14.2 BLANK)