TM 55-1930-209-14&P-19
Table 3-3. Preventive Maintenance Checks and Services for ROWPU System (Continued)
B -
Before
D -
Daily
Q - Quarterly
D -
During
W -
Weekly
S - Semiannually
A -
After
M -
Monthly
A - Annually
INTERVAL
ITEM
PROCEDURES
EQUIPMENT
ITEM
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
4) Clean oil breather element with dry-
cleaning solvent, type 2 (A-A-711).
Dry thoroughly.
5) Install oil breather element on body.
6) Install oil breather top, flatwasher,
lockwasher, and wingnut.
8E
RO Block
a. Grease RO block throttling valve R07 as
Throttling Valve
follows:
R07
1) Clean grease from RO block throttling
valve R07 using a clean, lint-free
cloth.
2) Use hand pump grease gun to pump
grease (MIL-G-10924) into bearings
until grease appears.
3) Wipe off excess grease.
8F
Alternator
a. Check alternator belt for looseness,
Alternator belt is
frays or cracks. Replace as necessary.
loose, frayed
If loose, adjust as follows:
or cracked.
1) Remove three nuts, bolts, lockwash-
ers, and flatwashers. Remove alterna-
tor guard.
2) Place straight edges from vibration
damper pulley to alternator pulley
to adjust.
b. Check alternator for loose mounting
hardware and wire connections. Tighten
or replace as necessary.
c. Check for damaged alternator. Alternator
If necessary, replace as follows: inoperable.
WARNING
To prevent electric shock, ensure battery
is disconnected before performing this
procedure.
3-28 Change 1