TM 55-1930-209-14&P-19
Table 15-1. Preventive Maintenance Checks and Services for Miscellaneous Equipment (Continued)
B -
Before
D -
Daily
Q - Quarterly
D -
During
W -
Weekly
S - Semiannually
A -
After
M -
Monthly
A - Annually
INTERVAL
ITEM
PROCEDURES
EQUIPMENT
ITEM
TO BE
CHECK FOR AND HAVE
IS NOT READY/
NO.
INSPECTED
REPAIRED OR ADJUSTED
AVAILABLE IF
B D A D W M Q S A
AS NECESSARY
g. Close incinerating toilet lid after each
use.
h.
Make sure toilet and cubicle are clean.
i.
Remove rust and corrosion. Touch up
paint in accordance with TB 43-0144 as
necessary. Do not paint threads or
labels.
5
Bilge System
a.
Wipe all components clean, especially
sludge tank liquid level indicator glass
cover.
b.
Check for leaks and damaged or missing
Class III leaks.
securements and fasteners. Repair,
replace and/or tighten if required.
c.
Check wiring for loose connections and
Cables frayed.
frayed cables. Secure, repair, or replace
cables as necessary.
d.
Check that strainer basket is clean and
properly installed. Clean or replace bas-
ket as follows:
1) Loosen yoke screw until yoke swings
free.
2) Pull basket handle straight up to
remove basket. Go to step 3 to clean
and step 4 to replace basket.
CAUTION
Do NOT have basket well open for more
than 10 minutes. Diverter plug does not
completely cut off water and water will
seep into open well.
15-11