TM 55-1930-209-14&P-2c.Replacing strainer basket.(1)Lower cleaned basket, or new basket if existing basket cannot be cleaned, into well.(2)Swing yoke over basket well until end fits over stud.(3)Be sure O-rings on cover rest in machined grooves before tightening yoke screw securely. DoNOT overtighten.4-7.2.3.3 Replacementa.Removal.(1)Close following Seawater System (SW) valves:STRAINERLOCATIONVALVESVoid 2 starboardSW1, SW9 (Strainer 1)SW2, SW10 (Strainer 2)Void 2 portSW3, SW27 (Strainer 3)Void 4 portSW37, SW38(2)Disconnect piping(3)Remove mounting hardware.(4)Remove strainer.b.Installation. Install strainer in reverse order of removal in step a.4-7.2.4 Strainer Inlet and outlet pressure gauges4-7.2.4.1 Cleaning and Inspectiona.Wipe clean pressure gauges listed below with rag dampened with hot soapy water or an approvedsolvent. Wipe dry with clean cloth.PRESSUREGAUGELOCATIONBARGEVoid 2 starboard1, 2, and 3Void 2 port1, 2, and 3Void 4 port2 and 3b.Visually inspect for damage or leaks. Correct leak by tightening or replacing connector or tubing.Replace damaged pressure gauge.4-7.2.4.2 Replacementa.Removal.(1)Close following seawater valves as necessary:VALVEVALVELOCATIONBARGESW31 or SW32Void 2 starboard1, 2, and 3SW33 or SW34Void 2 starboard1, 2, and 3SW34 or SW35Void 2 port1, 2, and 3SW45 or SW46Void 4 port2 and 34-11