SHUTOFF AND ALARM SYSTEM COMPONENTS
TESTING AND ADJUSTING
5.
Make sure the set for start button (13) is in the
RUN position.
6.
Connect the 8S4627 Circuit Tester between the
common terminal and the normally closed
terminal. The light of the circuit tester must not
be activated.
7.
Turn screw (14) clockwise until the light of the
circuit tester is activated.
8.
Tighten the locknut.
WIRING CONNECTIONS
D. Normally closed B terminal Normally open W
terminal F. Common R terminal
9.
To check the adjustment, close shutoff fitting (7)
and open shutoff fitting (6).
10.
Connect the wires to the normally closed
terminal.
11.
Close shutoff fitting (6) and slowly open shutoff
fitting (7) until the engine stops or the alarm
operates.
12.
The pressure gauge must show the correct
pressure specification of the switch as the
engine stops or the alarm operates.
CONTACTOR SWITCH FOR WATER TEMPERATURE
Tools Needed:
Fabricated heat sink.
2F7112 Thermometer.
3J5389 Plug.
8S4627 Circuit Tester.
Method of Checking
1.
Make a heat sink as shown. Material can be
brass, steel or cast iron. Drill a 23/32 in. hole
through the plate and use a tap to make 1/2 in.
NPT threads.
2.
Put marks on the two contactor wires that
connect the contactor to the circuit. Disconnect
the two wires.
HEAT SINK
[Dimensions in mm (in.)]
3.
Remove the contactor and install a 3J5389 Plug.
Install the contactor switch in the heat sink.
4.
Put the heat sink and contactor in water as
shown. Use blocks to support the heat sink at
surface level.
5.
Connect the 8S4627 Circuit Tester between the
wires that connected the contactor to the circuit.
TEST OF CONTACTOR SWITCH
1. 2F7112 Thermometer. 2 Fabricated heat sink.
6.
Put the 2F7112 Thermometer in the water.
7.
Use a torch to heat the water to the temperature
range at which the contactor must activate. If
the circuit tester light does not come on within
the
temperature
range
given
in
the
specifications, make a replacement of the
contactor.
8.
Let the water temperature go down. If the circuit
tester
light
does
not
go
out
within
the
temperature range given in the specifications,
make
a
replacement
of
the
contactor.
66