TM 10-4320-317-13
CAUTION
To prevent leakage, dose both cam arms at the same time.
Do not strike cam arms too close. Damage to couplings could result.
(40) Connect two reducers (1) to two discharge hoses (4) of third wye-connection (5). Close cam arms.
(41) Push cam arms on ends of two 2-inch elbow valves (6) forward to open position.
(42) Connect two elbow valves (6) to two discharge hoses (7) on second wye-connection (8). Close cam arms.
(43) Push cam arms on open ends of two elbow valves (6) forward to open position.
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms too close. Damage to couplings could result.
(44) Connect two dust plugs (9) to two elbow valves (6). Close cam arms.
(45) Install two nozzle stand assemblies. Spread tripod legs (1, Figure 2-27) and secure legs with rocks or embed
pointed ends in ground. Locate nozzle stand assemblies at convenient spots for hanging up distribution point
nozzles (2) and elbow valves (3).
Figure 2-27. Nozzle Stand Assembly
(46) Using locally available materials, construct tripod supports (1, Figure 2-28) on which to hang drinking water
storage bags (2). Hang water bags on tripods.
2-49