TM 10-4320-317-13
Figure 2-23. 125 GPM Pump
NOTE
The anti-seizing tape is to be wrapped in the same direction as the pipe threads.
(7)
Wrap anti-seizing tape (Item 10, Appendix E) around threads on female quick-disconnect coupling half (3).
Screw coupling half (3) into suction port (1) of 125 GPM pump.
(8)
Push cam arms (4) on quick-disconnect coupling half (3) forward to open position.
CAUTION
To prevent leakage, dose both cam arms at the same time.
Do not strike cam arms too dose. Damage to couplings could result.
(9)
Connect 2 in. X 20 ft rigid wall section hose assembly from storage tank to female quick-disconnect coupling
half (3) on pump. Close cam arms (4).
(10) Wrap anti-seize tape (Item 10, Appendix E) around threads on male quick-disconnect coupling half (5). Screw
male quick-disconnect coupling half (5) into discharge port (2) of 125 GPM pump.
(11) Connect 2 in. X 10 ft discharge hose to male quick-disconnect coupling half (5) on pump. Close cam arms.
2-44