TM 10-4610-215-24
TM 08580A-24/2
WARNING
Drycleaning solvent Fed. Spec. PD680 is potentially
dangerous. Avoid repeated and prolonged breathing of vapors
and skin contact. Do not use near open flame, arcing equipment
or other ignition sources. Always wear protective clothing and
eyewear.
(3) Clean motor using a stiff brush and cleaning solvent Fed. Spec. P-D-80.
(4) Allow to air dry.
Weight of backwash pump is 195 pounds (88 kg.) Attempting to
move it without proper equipment could cause serious injury.
Use equipment rated at 1 ton (0.91 tonne) or more to move
backwash pump.
(5) Move motor into shop.
(6) Remove pump from motor in accordance with paragraph 2-41.
(7) Remove four screws (1) from conduit box (5), gasket (3), and conduit box cover (2).
(8) Remove conduit box cover (2) and gasket (3) from conduit box (5). Discard gasket (3).
(9) Remove two bolts (4) from motor casing (25), gasket (6), and conduit box (5)
(10) Remove conduit box (5) and gasket (6) from motor casing (25). Discard gasket (6).
(11) Remove three screws (7) from fan-end plate (13) and cover (8).
(12) Remove fan cover (8) from fan-end plate (13).
(13) Loosen, but do not remove, clamp bolt (10) in hub of cooling fan (9).
(14) Spread clamp and remove cooling fan (9) from rotor shaft (18).
(15) Remove four nuts (11) from through-bolts (12).
(16) Remove four through-bolts (12) from pump-end plate (16), motor casing (25) and fan-end plate (13).
WARNING
3-34