c. Cleaning.
WARNING
Objects blown by compressed air can cause serious eye injury.
Always wear protective goggles when using compressed air.
(1) Blow out dirt inside motor casing with compressed air.
WARNING
Drycleaning solvent Fed. Spec. PD680 is potentially
dangerous. Avoid repeated and prolonged breathing of vapors
and skin contact. Do not use near open flame, arcing equipment
or other ignition sources. Always wear protective clothing and
eyewear.
(2) Clean dust and dirt from fan fins, rotor fans, inside fan cover, and both end plates with cleaning
solvent Fed. Spec. PD-680 and air dry.
(3)
(4)
P-D-680.
(5)
(6)
WARNING
Objects blown by compressed air can cause serious eye injury.
Always wear protective goggles when using compressed air.
Blow out any remaining dust and dirt.
Clean non-electrical metal components, including bearings, with cleaning solvent Fed. Spec.
WARNING
Solvent blown off or thrown off bearings can cause eye injury. Do
not spin ball bearings after washing.
Air dry parts.
Wrap dry bearings in a soft, clean, lintless cloth.
d. Inspection.
(1) Check metal parts, particularly cooling fan and rotor shaft, for signs of wear.
3-36