TM 10-4610-232-12
(15)
Setup the cyclone separator as shown in Figure 2-29.
Figure 2-29. Set-Up Cyclone Separator (Sheet 1 of 2)
(MODEL WTA-060 ONLY)
NOTE
Steps (a) through (j) apply to Model WTA-060 only.
NOTE
(MODEL WTA-060 ONLY)
When operating on well water with no convenient way to dispose of separator drain water it is allowable to disconnect
the separator drain hose (7) from one separator and attach the hose from the second separator to the drain connection
of the first. The separators will then act as a pressure drop device to keep the pressure in the ROWPU raw water
system from getting too high.
(a)
Position the frame on a fiat area of ground within easy reach of the raw water pump discharge hoses.
(b)
Press the cross bar of frame member (1) into the open channel of frame member (2) to form the triangular frame.
Pull out base until strap is tensioned.
(c)
Set one separator (3 or 4) in place on the frame by inserting the upper and lower flange into the slots in the cross
members. Place foot on frame to keep from tipping.
(d)
Push the mounted separator to the outside edge of the slots and set the remaining separator in its place.
(e)
Connect the separator discharge manifold (5) to one separator. Leave cam levers (8) open.
(f)
Push both separators together until the manifold connection firmly mates with the second separator. Finish
connection by closing hose cam levers (8).
2-60 Change 7