NOTE
When rolling a cotton hose, ensure it is dry and layed out with the white side facing up and
the side with the writing face down so when rolled the name of the hose will appear on the
outside. Begin rolling the hose at the end without the carrying straps and roll tightly,
keeping the edges even and neat. Once rolled, set the coil upright and press down on the
hose while inserting the metal buckle through the middle of the base, and fasten in carrying
configuration. If the hose is rolled correctly, the name will appear on the outside and will
not fall apart when carried with the strap.
(7)
Coil and place the four raw water discharge hoses (6) in the rear on top of raw water pump skid (5) in two stacks of two at
slanted angles.
(8)
Coil and place six waste out hoses (7) in front of the raw water discharge hoses (6) in two stacks of three at slanted
angles.
(9)
Coil and place two dispensing hoses with nozzles (8) in the rear on top of the raw water discharge hoses (6). Place one
hose on each stack.
(10)
Coil and place auxiliary hose (9) on top of the waste out hose stack on the right front side close to main control panel.
(11)
Coil and place the cleaning heat-up hose (10) on the lab table between the pump skids and the gate.
(12)
Place strainer assembly (11) on top of the waste out hose stacks with the large end to the left and the camlocking end to
the right so that it is flat. Ensure strainer body is upside down (flat side up and rounded side down).
NOTES
· When using any strap, ensure that all the slack is pulled out before tying down.
· Route straps over hose end of strainer assembly, not over the top of the strainer body.
(13)
Using two straps #6 (Model ROWPU-1) or two straps #13 (Model WTA-060), tie down strainer assembly (11) and hose
stacks using the two hooks on the front of lab table.
WARNING
Separator is heavy and can injure personnel. Always use two personnel to move separator.
(14)
On Model ROWPU-1, position the cyclone separator (12) (Figure 2-64, Sheet 2) upside down with the flat side of the
insert arm against the back wall of the ROWPU. On Model WTA-060, position the left separator (12) (Figure 2-64, Sheet
1) upside down against the back wall and then position the right separator (12) right side up, next to left separator (12).
(15)
On Model ROWPU-1, tie down separator (12) using two straps #7 (Figure 2-64, Sheet 2) and the hooks provided. Model
WTA-060 uses two straps #14 (Figure 2-64, Sheet 1).
(16)
Coil and place the NBC drain hose (13), two NBC operation hoses (14) and the funnel tubing (15) upright on the floor
between the cyclone separator(s) (12) and the lab table.
(17)
Stack storage boxes #3 and #4 (16, 17) on the end of lab table as shown in (Figure 2-64, Sheet 3).
(18)
Run strap #5 (Model ROWPU-1) or strap #8 (Model WTA-060) through handles of storage boxes (16, 17) and attach strap
#5 or strap #8 to lab table. Tighten strap #5 or strap #8.
2-130.2 Change 12