TM 10-4610-232-12
(33)
Tightly roll and place two sump drain hoses w/o fittings (30) on top of the sump drain hoses w/fittings (29) remembering to
keep the ends of the inside stack clear.
(34)
Stagger stack the last five raw water suction hoses (28), distribution pump suction hose (male to male end) (31), and the
distribution system hose (female to female end) (32) on top of the suction hose stack.
(35)
On Model ROWPU-1, the following couplings are placed on top of the sump drain hose stack:
a.
Distribution pump discharge (male) (33).
b.
Product shut-off valve (34).
c.
Raw water feed (small) (35).
d.
Raw water system (L-shaped) (36).
e.
Separator out pipe section (T-shaped) (37).
f.
Waste out (38).
g.
Special tee (39).
(36)
On Model WTA-060, the following couplings are placed on top of the sump drain hose stack:
a.
Distribution pump discharge (female) (40).
b.
Product shutoff valve (41).
c.
Raw water feed (large) (42).
d.
Raw water system (U-shaped) (43).
e.
Separator out pipe section (T-shaped) (44).
f.
Waste out (45).
g.
Special tee (46).
NOTE
Before packing the product out hoses and cyclone separator hose(s), ensure that they are
not interlocked. These hoses will be packed standing upright in a horse shoe configuration.
(37)
Position the five product out hoses (47) and one separator hose (48) (Model ROWPU-1) or two separator hoses (48)
(Model WTA-060), standing upright in horseshoe fashion with the coupling ends in the clear space provided on each side
of the sump drain hose stack.
(38)
Place the following items neatly inside the raw water suction hose stack in the following order:
a.
Two distribution pump suction hoses (small) (49).
b.
One raw water pump drain hose (50).
c.
One cyclone separator drain hose (51) (Model ROWPU-1) or two cyclone separator drain hoses (51) (Model WTA-
060).
d.
Priming pitcher (orange container) (52).
e.
Prime assist pump (53).
f.
Funnel (54).
(39)
Using the two straps #3 or straps #10 already in place, criss-cross the straps only over the stagger stacked hoses and
attach straps to the two floor hooks on the opposite side. Tighten straps so hose stack can not move from side to side.
WARNING
Each storage tank weighs 130 Ibs (59 kg). Three people are required to carry each tank.
(40)
Using strap #3 (Model ROWPU-1) or strap #12 (Model WTA-060), attach one end of strap to the floor hook in front of the
media filter and position the strap out of the way until needed.
(41)
Store two storage tanks (55) in an upright position and place both as far back between the media filter and cartridge filter
as possible.
2-130.4 Change 12