TM 10-4610-232-34
NOTE
Apply antiseize tape to pipe threads.
a. Install filter nozzle (37) inside tank (4).
a.1. Install distribution nozzles (34A) to hub (34B).
b. Install adapter (35) in coupling (36) and mount on hub assembly (34).
c. Install hub assembly (34) in tank (4). Secure with angle bracket (33), capscrew (30), Iockwasher (31 ) and washer
(32).
d. Install nut (26), seal (27), and coupling (29) on outlet pipe (28) and tighten nut (26).
e. Install nut (23) and gasket (24) on pipe assembly (22).
f. Install nut (21) and gasket (25) on pipe assembly (22).
g. Install pipe assembly (22) to hub assembly and coupling (29). Secure with nuts (21) and (23).
h. Install bracket (9). Secure with capscrews (17), washers (1 8), Iockwashers(19) and nuts (20).
i. Install nut (14), gasket (16) and coupling (12) on inlet pipe (1 5), Tighten nut (14),
j. Install nut (10) and seal (13) on pipe assembly(11).
k. Install pipe assembly (11) on coupling (12) and tighten nut (10).
1. Secure pipe assembly (11) with U-bolt (8), nut (5), Iockwasher (6) and washer (7).
INSTALLATION.
a. Refer to Figure 2-65 and install the NBC tank (4) as follows:
(1) Using suitable lifting equipment, place the NBC tank (4) in the doorway of the ROWPU.
(2) Move the NBC filter to its final position in the ROWPU.
(3) Secure the filter in position using capscrews (1 ), Iockwashers (2) and washers (3).
12-202.2 Change 1