TM 104610-232-34
a. Install nuts (31), studs (32), nuts (33), Iockwashers (34) and washers (35) in wall if they were removed.
b. Install the regulator body in plate (15) and secure in position with spacer (14), plates (12 and 13), nuts (9),
Iockwashers (10) and washers (1 1 ).
c. Connect air lines (6 and 7). Connect air line (8) by connecting coupling (27) to coupling (28).
d. Close manifold bleed valves (3).
e. Open valve (2) at the air tank.
f. Turn air regulator handle (5) clockwise to open the air supply.
g. Turn COMPRESSOR OFF/ON switch(1) to ON position.
h. Use soapy water solution to check for air leaks.
-----
2-209