TM 10-4610-239-24
TM 08580B-24/3
INSTALLATION.
CABLE
CAUTION
Improper connection of wiring will damage timer. Check tags before installation.
a. Slide compression nut (8) on cable (3). Slide gland retainer (25) and gland (10) on cable. (3).
b. Push leads from cable (3) through connector body (9) and tighten compression nut (8) to connector body (9).
c.
Insert red wire at position 5, yellow wire at position 4, green wire at position 3, white wire at position 2, and black
wire at position 1 on terminal board (7). Tighten setscrews (6).
WIRING
CAUTION
Improper connection of wiring will damage timer. Check tags before installation.
NOTE
Terminal board (12) requires that each marked position be manually opened with a small
instrument such as a small screwdriver so that the wire lead can be reinserted into the
terminal board.
a. Insert one end of red wire into position 5 on terminal board (12). Tighten setscrew (11). Insert other end of red
wire into position 5 on terminal board (7). Tighten setscrew (6).
b. Insert one end of yellow wire into position 2 on terminal board (12). Tighten setscrew (11). Insert other end of
yellow wire into position 4 on terminal board (7). Tighten setscrew (6).
c.
Insert one end of green wire into position 14 on terminal board (12). Tighten setscrew (11). Insert other end of
green wire into position 3 on terminal board (7). Tighten setscrew (6)
d. Insert one end of white wire into position 12 on terminal board (12). Tighten setscrew (11). Insert other end of
white wire into position 2 on terminal board (7). Tighten setscrew (6)
e. Insert one end of black wire into position 13 on terminal board (12). Tighten setscrew (11). Insert other end of
black wire into position 1 on terminal board (7). Tighten setscrew (6)
2-211