TM 10-4610-239-24
TM 08580B-24/3
INSTALLATION. (Cont)
BACKWASH TIMER ASSEMBLY
a. Position stagger and gasket assembly (23) inside control box (24) and install four screws (19).
CAUTION
Improper connection of pressure tubes to backwash timer will result in damage to timer.
Check attached tags before connecting tubes.
NOTE
Apply antiseize tape to male pipe threads before installation.
b. Install two pipe plugs (15).
c.
Install five elbows (16).
d. Install strainer (18).
e. Install three adapters (17)
f.
Connect eight pressure tubes (13) by attaching plastic compression nut (14.).
CAUTION
Installation of contacts in wrong connector sockets will result in malfunctions or damage
to equipment. Be sure contacts are installed as tagged.
g. Insert color coded tagged leads (black violet, orange, red, blue, and white) of cable (13) in positions 6, 7, 8, 9, 10,
and 11 of terminal board (12) and tighten setscrews.
LATCH ASSEMBLY
NOTE
There are six latch assemblies.
All are identical and all are attached in the same
manner. One is shown.
Position latch assembly (4) on control box (24) and install two new lock nuts (21) with two screws (20).
GASKET
Position gasket (22) on door (5) and glue in place.
2-212